EuroSun2008-5

Spectral method (SPM)

The spectral method is based on analyzing the transient temperature changes in the collector circuit after the pump is started [5; 6]. Temperature signals on a secondly basis are transformed with a Fourier transformation in the spectral range. A failure free training phase results in a characteristic vector and an uncertainty boundary. A measured vector out of this range indicates a failure. Only one extra temperature sensor about a meter after the collector exit in the collector pipe is necessary. Several larger failures could be recognized, especially in high flow systems. These are e. g. a 40 % reduction of collector performance, a 20 % change in pump power and air in the heat exchanger. However, a failure free training phase of at least half a year is necessary and that may be difficult or even impossible.

3.2. Fault Detection with Artificial Neural Networks (ANN)

The development of a neural network-based fault diagnostic system for the solar circuit is still in a research phase. The method consists of three steps. In the prediction module, artificial neural networks are trained with fault-free system operating data obtained from a TRNSYS model. The model is trained so that 4 temperature values (collector in and output and storage in and output) can be predicted for different environmental conditions. The input consists of weather data (global and beam radiation, ambient temperature, incidence angle, wind speed, relative humidity, flow availability and inlet temperature), together with one of the other measured temperature values. In the second step residual values are calculated, which characterize e. g. the actual temperature increase in the collector compared to the predicted one. In the last step a diagnosis module is run. The failure detection was only successfully tested for introduced failures in TRNSYS [7; 8]. Since the network was trained with TRNSYS, and there are no measurement uncertainties it has to be seen how it compares to real system behaviour.

EuroSun2008-5

Automatic Control System

The whole automation system is mainly divided into two parts: one part is the hardware equipments consisted of all kinds of devices used in the testing system; the other part …

The application of the regulations minimal solar collector area

Following the new regulations, a three bedrooms autonomous zone must have a minimal collector area of 4 m2 independently of the climate zone were is located. From the simulations results …

Measured sequences used for validation purposes

The comparison of experimental and calculated instantaneous power results, obtained after the different approaches presented in the previous section, is based on instantaneous efficiency measurements for a CPC collector (C …

Как с нами связаться:

Украина:
г.Александрия
тел./факс +38 05235  77193 Бухгалтерия

+38 050 457 13 30 — Рашид - продажи новинок
e-mail: msd@msd.com.ua
Схема проезда к производственному офису:
Схема проезда к МСД

Партнеры МСД

Контакты для заказов оборудования:

Внимание! На этом сайте большинство материалов - техническая литература в помощь предпринимателю. Так же большинство производственного оборудования сегодня не актуально. Уточнить можно по почте: Эл. почта: msd@msd.com.ua

+38 050 512 1194 Александр
- телефон для консультаций и заказов спец.оборудования, дробилок, уловителей, дражираторов, гереторных насосов и инженерных решений.