Подпись: is very installed.For the design of a solar-powered desalination system, the question of energy efficiency important, since the investment costs mainly depend on the area of solar collectors to be Also, the power consumption of the auxiliary equipment (for example the pump) which will be supplied by photovoltaic (PV) has an important influence on the total system costs. Therefore, the system design has to focus on a very good heat recovery function to minimize the need for thermal energy. Heat recovery can be achieved by an external heat exchanger or by an internal heat recovery function, where the feed water is used as coolant for the condenser channel. The internal construction principle respectively the spiral wound geometry of the MD module with integrated heat recovery is shown in figure 3.The technical specifications of the MD modules constructed by Fraunhofer ISE are:

• hydrophobic membrane, mean pore size 0.1 - 0.4pm

• height 450 - 800 mm

• diameter 300 - 400 mm

• membrane area 7 m2 - 12m2

• feed temperature at evaporator inlet 60 - 85 °C

• maximum feed volume flow 500 l/h

• specific thermal energy consumption 100 - 260 kWh/m3distillate

Подпись: Fig 3: Principle of the channel construction with integrated heat exchanger and design of a the spiral wound set up
image164

distillate output 10-40 l/h

EuroSun2008-2

Validation of the library components

The validation of the models is necessary to ensure that the calculated results are valid. Furthermore it is to proof what differences consist due to the assumptions made in the …

Solar industrial process heat plants in operation

Data gathered in the framework of the IEA Task 33/IV include comprehensive information about the geographical distribution of the solar thermal plants, the industrial sectors addressed, the specific processes, the …

Experimental Investigations On Solar Driven Desalination Systems Using Membrane Distillation

J. Koschikowski*, M. Wieghaus*, M. Rommel*, Vicente Subiela Ortin**, Baltasar Penate Suarez**, Juana Rosa Betancort Rodriguez** * Fraunhofer Institute for Solar Energy Systems ISEHeidenhofstr.2,79110 Freiburg, GermanyTel +49-761-4588-5294Fax +49-761-4588-9000email ioako@ise. fhg. …

Как с нами связаться:

Украина:
г.Александрия
тел./факс +38 05235  77193 Бухгалтерия

+38 050 457 13 30 — Рашид - продажи новинок
e-mail: msd@msd.com.ua
Схема проезда к производственному офису:
Схема проезда к МСД

Партнеры МСД

Контакты для заказов оборудования:

Внимание! На этом сайте большинство материалов - техническая литература в помощь предпринимателю. Так же большинство производственного оборудования сегодня не актуально. Уточнить можно по почте: Эл. почта: msd@msd.com.ua

+38 050 512 1194 Александр
- телефон для консультаций и заказов спец.оборудования, дробилок, уловителей, дражираторов, гереторных насосов и инженерных решений.